The two-wire decoder version of Hunter’s most powerful controller for command of large and sophisticated sites.
The versatility of the ACC controller grows even more powerful with the addition of the all-new, two-wire decoder system from Hunter. ACC-99D uses two-wire decoders to control up to 99 stations without giving up the arsenal of features in the ACC! The powerful overlapping, stacking array of programs, along with ACC’s dual programmable pump/master valve outputs, real-time flow monitoring, and up to four programmable sensor inputs, take full advantage of this controller’s high capacity.
Decoder installations are the fastest growing technology in irrigation control. Why? Because it saves copper wire, simplifies troubleshooting, permits rapid addition of new stations, minimizes trenching, and now, permits remote sensor operation over the two-wire path. The ACC-99D, Hunter's most powerful controller teamed with the most versatile decoders in the industry…an unbeatable combination for large sites with changing needs.
FEATURES & BENEFITS
Real-time flow monitoring in standalone mode
Learns flow by station and automatically responds to incorrect flow
Simple two-wire decoder installation
Up to 99 stations plus the ability to have remote sensors
Up to 6 two-wire paths of up to 15,000 feet/4.5 kilometers each
Economical wiring for the largest systems
Diagnostic output LEDs and electrical current display
Displays station activity and line status at a glance
Field programmable decoders with built-in surge protection
No complicated serial numbers or extra lightning devices
Easy modular upgrade to 2-way communication with central control
Simple plug-in modules upgrade ACC to hardwire, modem, or radio control
Programmable pump/master valve assignments
Run pumps and master valves via conventional or decoder outputs
6 fully-independent programs (plus 4 custom programs)
Standard programs each have separate day cycles and 10 start times, offering total flexibility for complex landscapes
Non-volatile 100-year memory
Program data is retained during power outages, no battery required
Multiple sensor hookups
Works with Hunter Solar Sync sensor for automatic smart weather adjustment and up to 4 (four) Clik sensors for rain, freeze and wind shutdowns
SPECIFICATIONS
MODELS
ACC-99D – 2-Wire Decoder Controller with 99 station capacity, wall mount metal cabinet
ACC-99DPP – 2-Wire Decoder Controller with 99 station capacity, plastic pedestal
ICD-100 – Single-station decoder with surge suppression and ground wire
ICD-200 – Two-station decoder with surge suppression and ground wire
ICD-400 – Four-station decoder with surge suppression and ground wire
ICD-600 – Six-station decoder with surge suppression and ground wire
ICD-SEN – Two input sensor decoder with surge suppression and ground wire
IDWIRE1 – 14 AWG/1.6 mm dia. decoder wire (up to 10,000 ft./3 km)
IDWIRE2 – 12 AWG/2mm dia. decoder wire (up to 15,000 ft./4.5 km)
HFS – Hunter flow sensor, requires the use of an FCT-xxx
ACC-PED – Metal Pedestal for use with ACC-99D
DIMENSIONS
• ACC-99D Cabinet : 12 3⁄8" H x 15 1/2" W x 6 7/16" D
(31.4 cm H x 39.4 cm W x 16.4 cm D)
• ACC-99D Metal Pedestal: 36 1⁄8" H x 15 1/2" W x 5" D
(91.5 cm H x 39.4 cm W x 12.7 cm D)
• ACC-99D Plastic Pedestal: 38 3⁄8" H x 21 9⁄16" W x 15 7⁄8" D
(97.5 cm H x 54.6 cm W x 40.3 cm D)
• Decoders:
ICD-100, 200, ICD-SEN - 3 5⁄8" H* x 1 1/2" W x 1/2" D
(92 mm H* x 38 mm W x 12.7 mm D)
ICD-400, 600 - 3 5⁄8" H* x 1 3/4" W x 1 1/2" D
(92 mm H* x 46 mm W x 38 mm D)
• Wire leads (all) - 18" L, 18 AWG dia.
(46 cm L, 1 mm dia.)
*Not including wire leads.
SPECIFICATIONS & FEATURES
• Transformer Input: 120/230VAC, 50/60 Hz, 2A max at 120V, 1A max at 230V.ACC Decoder Group
• Transformer output: 24VAC, 4A, @ 120VAC
• Decoder Line (path) output: 34V peak-to-peak
• Decoder Power draw: 40 mA per active output
• Solenoid capacity: 2 standard 24 VAC Hunter solenoids per output within 100 ft./33 m runs, up to 14 solenoids max simultaneous (includes dual P/MV outputs)
• Wiring, Decoder to solenoid: standard pair 18 AWG/1 mm to 100 ft./33 m (twisted improves surge resistance)
• 6 two-wire output paths to field decoders
• Two-way confirmation of decoder activation
• Two-way monitoring of sensor connections (ICD-SEN)
• Diagnostic LEDs with line status, signal activity, decoder and status
• Programmable decoder station IDs (from controller panel)
ACC-99D Decoder Systems include all standard features of the ACC controller, including:
• 6 automatic programs, with 4 custom manual (auxiliary) programs
• Dual pump/master valve outputs programmable by station
• 1 flow meter (diagnostics to station level) and up to 4 sensor inputs (programmable to program level)
• Programmable overlap or SmartStack by program with simultaneous station groups.
• Seasonal adjust, 0 to 300% in 1% increments by program
• Flow learning mode by station with programmable alarm thresholds
• Station run times up to 6 hours with programmable delay between stations (up to 4 hours)
• Self-diagnostic circuit breaker skips shorted stations and continues watering
• SmartPort® equipped for wireless remote control
• Test program feature allows for quick system checks
• IMMS 2.0 central system compatible
• Upgrade to "smart" weather based watering with Solar Sync Sensor
• Real-time Flow Monitoring capability built in, with actual flow histories (in GPM or metric) available when connected to Hunter HFS or other compatible flow meters.
• Flow-learning mode by station, with station-level diagnostics and alarm shutdowns.
• Easy Retrieve™ backup feature can restore schedules, run times, names and other settings to a saved setup
Not intended for use with the ET System - See Solar Sync for smart weather adjustment!
| SPECIFICATION GUIDE | ||
| EXAMPLE: ACC - 99D - PED | ||
| MODEL ACC |
FEATURES 99D = 2-Wire Decoder Controller with 99 Station Capacity, Metal Cabinet 99DPP = 2-Wire Decoder Controller with 99 Station Capacity, Plastic Pedestal |
OPTIONS USER INSTALLED PED = Optional Metal Pedestal |
| ICD IDWIRE1 IDWIRE2 |
100 = Single-station Decoder with Surge Suppression and Ground Wire 200 = Two-station Decoder with Surge Suppression and Ground Wire 400 = Four-station Decoder with Surge Suppression and Ground Wire 600 = Six-station Decoder with Surge Suppression and Ground Wire SEN = Two Input Sensor Decoder with Surge Suppression and Ground Wire 14 Awg Decoder Wire (Up to 10,000 Ft./3km) 12 Awg Decoder Wire (Up to 15,000 Ft./4.5km |
|
| ACC-COM | HWR = Hardwire Connection Communication Module for “Satellite” Installations POTS = Regular Dial-up Telephone (RJ-11) Connection Communication Module for “Satellite” Installations GSM = Cellular Connection Communication Module for “Satellite” Installations GSM-E = Cellular Connection Communication Module (Cell Phone & Antenna Included) for International “Satellite” Installations |
|
| ACC-HWIM RAD3 |
Terminal for Hardwire Connections (In- and Outbound Wire) UHF Radio Communications Module (Antenna not Included) |
|
| HFS | Hunter Flow Sensor, requires the use of an FCT-xxx tee fitting | |
LITERATURE
ACC Decoder Controller Brochure (765.66 Kb)
ACC Decoder Controller Owner's Manual (4.46 Mb)
WATCH SUPPORT VIDEOS
Controller Series: Canceling a Delay |
Controller Series: Programming Odd & Even Days and Programming Interval Watering |
Controller Series - Programming Multiple Programs - Part 1 of 4: Introduction, Time/Date |
Controller Series - Programming Multiple Programs - Part 2 of 4: Program A |
Controller Series - Programming Multiple Programs - Part 3 of 4: Program B |
Controller Series - Programming Multiple Programs - Part 4 of 4: Other Modes |
Controller Series: Canceling Extra Start Times |
Controller Series - Reset |
Controller Series - Controllers - Display Troubleshooting |